BENEFITS
- Safety first - A fully enclosed structure
- Green and clean – No oil mist to the environment
- A new level of control
- Easy to learn - One common platform
- Less installation time – No special alignment
- Easy plug-in for sensors
- 25% fewer wear parts – 50% more reliable
- Best cooling efficiency in the market
- Low vibration level – High grade of isolation
- Improved standard scope of supply
- A new generation of true 1800 RPM compressors
Technical Data | ||||
---|---|---|---|---|
Performance | 50 Hz (30 bar) | 60 Hz (30 bar) | ||
Speed (RPM) | 1475 | 1775 | ||
Charging capacity (m³/h)* | 270 | 330 | ||
Power requirement (kW) | 53 | 62 | ||
Heat dissipation (kCal/h) | 42980 | 50716 | ||
Cooling air requirement (m³/h) | 3600 | 4300 | ||
Cooling water requirement (l/min) | 65 | 80 | ||
*Charging capacity is from ambient pressure to final pressure. | ||||
Design | ||||
No. of cylinders | 2 | |||
Cylinder arrangement | 90° V | |||
No. of compression stages | 2 | |||
Cooling | Fresh water | |||
Valve LP | 1 plate valve | |||
Valve HP | 1 reed valve | |||
Lubrication | ||||
Oil type | Synthetic oil (see approved list) | |||
Sump capacity | 23 litres | |||
Lubrication system | Pressure | |||
Operating parameters | ||||
Maximum delivery pressure | 30 barg | |||
Max. ambient temperature compressor | 55°C | |||
Max. ambient temp. controller | 55°C | |||
Max. ambient temp. electric motor | 45°C (55°C on request) | |||
Outlet air temperature | Approx. 10-15°C above CW inlet temperature (CW design temp. 36°C) | |||
Max. noise level | 98 dBA | |||
Max. vibration level | 30 mm/s-RMS | |||
Min. isolation grade | 90 % | |||
Safety valve set point HP | 3 barg above HP | |||
Safety valve cooling water | 6 barg | |||
Rotation | Counterclockwise (looking at compressor front) | |||
Dimensions & weight | ||||
Weight (compressor/el.motor) | 1266 kg | |||
Dimensions | 1720 x 1260 x 1110 mm (L x W x H) | |||
Compressor paint | ||||
Sperre silver | Powder coated RAL 9006 | |||
Sperre green | Powder coated Munzell 7,5 BG 7/2 | |||
Other colors | Option | |||
Mechanical components | Integrated | Loose | ||
Non return valve air outlet | ■ | |||
Oil & Water separator LP | ■ | |||
Oil & Water separator HP | ■ | |||
1st stage safety valve | ■ | |||
2nd stage safety valve | ■ | |||
Safety valve cooling water | ■ | |||
Oil level sight glass | ■ | |||
Air suction filter | ■ | |||
Inter- and after cooler | ■ | |||
Three vibration isolators | ■ | |||
One lifting lug | ■ | |||
Flexible hose air outlet | ■ | |||
Flexible hose water inlet | ■ | |||
Flexible hose water outlet | ■ | |||
Flexible hoses drain LP/HP | ■ | |||
Electrical components | Integrated | Loose | ||
Local starter with extended controller | ■ | |||
Transmitter LP for alarms and stops | ■ | |||
Transmitter HP for alarms and stops | ■ | |||
Transmitter temp. outlet for alarms and stops | ■ | |||
Transmitter oil pressure for alarms and stops | ■ | |||
Solenoid valves for drain / unloading LP/HP | ■ | |||
Options | Integrated | Loose | ||
Cooling water pump | ■ | |||
Central starter with extended controller | ■ | |||
Central starter with basic controller | ■ | |||
Local starter with basic controller | ■ | |||
Spares according to class recommendation | ■ | |||
Others | Included | Not included | ||
Manufacturers test protocol | ■ | |||
Class certificate | ■ | |||
Spares according to makers recommendation | ■ |