Compressor Aircooled XA008 - 30 Bar
Benefits
 Safety first - A fully enclosed structure  Green and clean – No oil mist to the environment  A new level of control  Easy to learn - One common platform  Less installation time – No special alignment  Easy plug-in for sensors  25% fewer wear parts – 50% more reliable  Best cooling efficiency in the market  Low vibration level – High grade of isolation  Improved standard scope of supply  A new generation of true 1800 RPM compressors
|
Charging capacity at 1775 / 1475 RPM
|
9 / 7 m3/h
|
|
Power requirements 1775 / 1475 RPM
|
2.1 / 1.7 kW
|
|
Heat dissipation to ambient 1775 / 1475 RPM
|
1.9 / 1.6 kW
|
| Weight complete (standard motor) |
130 kg
|
| Dimensions |
740 * 500 * 710 mm (L * W * H)
|
Design |
| No. of cylinders |
1
|
| No. of compression stages |
2
|
| Cooling |
Air cooled
|
| Valves LP |
1 Reed valve
|
| Valves HP |
2 Reed valve
|
Lubrication |
| Oil type |
X-range oil recommendation See approved list
|
| Oil volume |
3.5 liters
|
| Lubrication system |
Splash
|
Operation parameters |
| Max. delivery pressure |
40 barg
|
| Max. ambient temp. compressor |
55oC
|
| Max. ambient temp. controller |
55oC
|
| Max. ambient temp. electric motor |
45oC (55oC on request)
|
| Outlet air temperature |
Approx. 25oC above ambient
|
| Max. noise level |
91 dBA
|
| Max. vibration level |
15 mm/s-RMS
|
| Min. isolation grade |
90 %
| | Safety valve set point HP | 3 barg above HP |
| Rotation | Counterclockwise (looking at compressor front) |
Compressor paint |
| Sperre silver | Powder coated RAL 9006 |
| Sperre green | Powder coated Munzell 7,5 BG 7/2 |
| Other colors | Option |
Mechanical components |
Integrated |
Loose |
| Non return valve air outlet | ■ | |
| Oil & Water separator HP | ■ | |
| 1st stage safety valve | ■ | |
| 2nd stage safety valve | ■ | |
| Oil level sight glass | ■ | |
| Air suction filter | ■ | |
| Inter- and after cooler | ■ | |
| Three vibration isolators | ■ | |
| One lifting lug | ■ | |
| Flexible hose air outlet | | ■ |
| Flexible hose drain | | ■ |
Electrical components |
Integrated |
Loose |
| Local starter with extended controller | | ■ |
| Transmitter LP for alarms and stops | ■ | |
| Transmitter HP for alarms and stops | ■ | |
| Transmitter temp. outlet for alarms and stops | ■ | |
| Transmitter oil level for alarms and stops | ■ | |
| Solenoid valve for drain / unloading | ■ | |
Options |
Integrated |
Loose |
| Central starter with extended controller | | ■ |
| Central starter with basic controller | | ■ |
| Local starter with basic controller | | ■ |
| Spares according to class recommendation | | ■ |
Others |
|
|
| Manufacturers test protocol | ■ | |
| Class certificate | ■ | |
| Spares according to makers recommendation | ■ | |
Sperre is not responsible for any errors that may appear in these datasheets.
We reserve the right to change specifications and technical data without notice.
|
|
|
|