Technical data HV1/85

General description:

Model HV1/85 is a one cylinder, double acting, two stage water cooled compressor.

The compressor is mounted together with an electric motor on a well stiffened foundation with a flexible coupling between the flywheel and drive flange.

Two coolers are fitted in the compressor cylinder block. The first serves to cool the air after first stage compression, the second provides cooling after second stage compression.
The cooling water intake and outlet are located so that the water circulates through the cylinder block and ensures efficient cooling of the air and cylinder walls.

Design particulars:

Design:
Nos. of cylinders 1
Cylinder arrangement
Nos. of compression stages 2
Cooling Water
Cooling system
Valves LP/HP: Plate valves (suction and delivery)
Dimensions:
Cylinder diameter LP/HP: 85 mm/77 mm
Stroke 85 mm
Lubrication:
Sump capacity 1,5 litres
Lubrication system Splash
Operating Parameters:
Maximum delivery pressure 40 bar
Maximum ambient temperature 45ºC (55ºC on request)
Normal temperature outlet air Approx. 20ºC above cooling water outlet
Safety valves set point 10% above stage pressure
Maximum speed 1200 RPM
Rotation Counter-clockwise (looking at the drive end)

  50 Hz 60 Hz
Speed (rpm) 725 975 875 1150
Capacity (Nm3/h) 14 19 17 22
Power request (kW) 3.0 4.4 3.7 5.1
Heat dissipation (kcal/h) 2193 3216 2704 3727
Cooling water req. (l/min) 3 4 4 5

Attachments/downloads

Sperre is not responsible for any errors that may appear in these datasheets.
We reserve the right to change specifications and technical data without notice.