General description:
Model HV1/156 is a one cylinder,double acting, two stage water cooled compressor.
The compressor is mounted together with an electric motor on a well stiffened foundation with a flexible coupling between the flywheel and drive flange.
Bearings are pressure lubricated by an oil pump gear driven by the crankshaft.
Two coolers are fitted in the compressor cylinder block. The first serves to cool the air after first stage compression, the second provides cooling after second stage compression.
The cooling water intake and outlet are located so that the water circulates through the cylinder block and ensures efficient cooling of the air and cylinder walls. Design particulars:
| Design: |
| Nos. of cylinders |
1 |
| Cylinder arrangement |
|
| Nos. of compression stages |
2 |
| Cooling |
Water |
| Cooling system |
|
| Valves |
LP/HP: Concentric |
| Dimensions: |
| Cylinder diameter |
LP/HP: 156 mm/140mm |
| Stroke |
100 mm |
| Lubrication: |
| Sump capacity |
4 litres |
| Lubrication system |
Pressure |
| Operating Parameters: |
| Maximum delivery pressure |
40 bar |
| Maximum ambient temperature |
45ºC (55ºC on request) |
| Normal temperature outlet air |
Approx. 20ºC above cooling water outlet |
| Safety valves set point |
10% above stage pressure |
| Maximum speed |
1200 RPM |
| Rotation |
Counter-clockwise (looking at the drive end) |
| |
50 Hz |
60 Hz |
| Speed (rpm) |
725 | 975 |
875 | 1150 |
| Capacity (Nm3/h) |
60 | 81 |
72 | 94 |
| Power request (kW) |
13.3 | 18.4 |
15.5 | 20.6 |
| Heat dissipation (kcal/h) |
9720 | 13447 |
11328 | 15055 |
| Cooling water req. (l/min) |
14 | 19 |
16 | 21 |
Capacity quoted are bottle charging rates, 0-30 bar.