Technical data HL2/90
General description:
Model HL2/90 is a two stage 90º V-compressor.
Cylinders and compressed air coolers are air-cooled. Cooling air is supplied by a well-dimensioned fan.
Bearings and cylinders walls are splash lubricated.
The compressor and motor are normally supplied mounted together on a foundation, and connected by means of a heavy-duty flexible coupling.
Both electrical and diesel engine driven versions are available. Design particulars:
| Design: |
| Nos. of cylinders |
2 |
| Cylinder arrangement |
90º V |
| Nos. of compression stages |
2 |
| Cooling |
Air |
| Cooling system |
Direct driven axial fan |
| Valves |
LP: Reed valve, HP: Concentric plate valve |
| Dimensions: |
| Cylinder diameter |
LP:90 mm, HP:50 mm |
| Stroke |
80 mm |
| Lubrication: |
| Sump capacity |
4 litres |
| Lubrication system |
Splash |
| Operating Parameters: |
| Maximum delivery pressure |
40 bar |
| Maximum ambient temperature |
45ºC (55ºC on request) |
| Normal temperature outlet air |
Approx. 10ºC above ambient |
| Safety valves set point |
10% above stage pressure |
| Maximum speed |
1800 RPM |
| Rotation |
Counter-clockwise (looking at the drive end) |
| |
50 Hz |
60 Hz |
| Speed (rpm) |
975 | 1450 |
1150 | 1750 |
| Capacity (Nm3/h) |
23 | 34 |
27 | 38 |
| Power request (kW) |
4.8 | 7.6 |
5.9 | 10.2 |
| Heat dissipation (kcal/h) |
3670 | 5820 |
4520 | 7810 |
| Cooling water req. (l/min) |
| |
| |
Sperre is not responsible for any errors that may appear in these datasheets.