Technical data HL2/160

General description:

Model HL2/160 is a two stage 90º V-compressor.

Cylinders and compressed air coolers are air-cooled. Cooling air is supplied by a well-dimensioned fan.

Bearings and cylinders walls are splash lubricated.

The compressor and motor are normally supplied mounted together on a foundation,and connected by means of a heavy-duty flexible coupling.

Both electrical and diesel engine driven versions are available.

Design particulars:

Design:
Nos. of cylinders 2
Cylinder arrangement 90º V
Nos. of compression stages 2
Cooling Air
Cooling system Direct driven axial fan
Valves Concentric plate valve
Dimensions:
Cylinder diameter 160 mm
Stroke 100 mm
Lubrication:
Sump capacity 10 litres
Lubrication system Splash
Operating Parameters:
Maximum delivery pressure 40 bar
Maximum ambient temperature 45ºC (55ºC on request)
Normal temperature outlet air Approx. 15ºC above ambient
Safety valves set point 10% above stage pressure
Maximum speed 1800 RPM
Rotation Counter-clockwise (looking at the drive end)

  50 Hz 60 Hz
Speed (rpm) 975 1450 1150 1750
Capacity (Nm3/h) 96 140 114 160
Power request (kW) 20.0 30.5 24.2 37.0
Heat dissipation (kcal/h) 15480 23607 18731 27050
Cooling water req. (l/min)

Attachments/downloads

Sperre is not responsible for any errors that may appear in these datasheets.